daily, called for variety of devices -10 to 25 numbers Installing different sort of waste Tracking systems ideally Incineration as well as others for the state Jammu & & Kashmir India maker and also retailer of various Incinerator and other items. Please be kept in mind that we are a leading Bangladeshi company house dealing […]
Incinerator Items/Model HICLOVER YD30(PLC)     Burn Rate (Average) 15kg/hour Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 360L(0.36M3) Internal Dimensions 100x60x60cm Secondary Chamber 200L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V  Power 0.5Kw Burner Type Italy Brand Oil Consumption (kg/hour) 12 N.Gas Consumption (m3n/hour) 9.8–20 Temperature Monitor Yes Temperature Thermometer […]
shed between 5000-10000 pound per hour.Mostly waste from petroleum storage tanks. Building and construction, installment and 6 months upkeep expense including specifications.CMSD for Double Chamber Rotating Klin Kind Incinerator (1st Chamber temperatur less than 850 level centrigrade & & 2nd Chamber Temperature Level less than 1200 c with exhaust pipeline 100 meter long with discharge […]
Aeration gate valve,Burner fuel pump,Circuit board (LM44.255C2BT), controller for Riello FS10 gas burner,Emergency push button, https://www.haiwos.com/#!/Incinerator-Spare-Parts/c/122963267  https://www.haiwos.com/#!/Waste-Incinerators/c/122950677  Fire proof flange gasket,Flexible Conduit,Fuel filter,Ignition transformer, Incinerator Automatic Protection Operator(APO) Controller, Nut for Temperature Thermocouple-Temperature  Probe,PLC auto control incinerator, Solenoid,Stainless steel tension wire,Temperature display controller K type, Temperature display controller S type
Local waste incinerator amounts and capacities will be made for 24-hour 7-day-a-week continuous operation. Incinerators shall be capable of processing both moist and also dry material and also working on diesel fuel, JP-8 gas, or waste oil; visit Plumbing for gasoline storage system needs. The complying with will be provided as a minimum: Strengthened concrete […]
1) Power Supply: ( a) Keys Supply: ( I) Solitary Phase supply; 220– 240V, 50Hz ( ii) Three Stage supply; 380– 415V, 50Hz ( iii) The power supply electric outlet (sockets) for single phase distribution system in the hospital is three hooks and also complies with BS1363. (b) Change: ( I) Mains change is an […]
https://www.haiwos.com/#!/Model-TS10-Incinerator-with-wet-scrubber-Spray-Tower-and-Defogging-Tower/p/472484002/category=0  Incinerator Items/Model HICLOVER TS10(PLC) Burn Rate (Average) 10-20 kg/hour Feed Capacity(Average) 20kg/feeding Control Mode PLC Automatic Primary Combustion Chamber 100L Internal Dimensions 50x50x40cm Secondary Chamber 50L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Burner Type Italy Brand Oil Consumption (kg/hour) 6 N.Gas Consumption (m3n/hour) *** Temperature Monitor Yes Temperature Thermometer […]
Incinerator but the dimension of chamber > > 2000 x >> 1200 mm. Plan for burn FLUID Waste +/- 20 liter/hr. C: The amount of set can we place in everyday basis daily. Sustained by Heavy OIL Burner.waste disposal incinerator, with the ability of coping with both wet and totally dry rubbish. That include home […]
1. I. Dimension of the Incinerator 4,410 W x 3,037 L x 4,836 H mm II. Ability of the Incinerator Medical waste 50 kg/hr. Set feeding (low level calorie value: 4,000 5,000 kcal/kg) III. Utility Utility problem for the incineration devices operating is the adhering to. 1) Gas: Light oil or Kerosene 2) Electric Power […]
  –          150 KG/HR –          Compliant with EU principles, Directive 2000/76/EC –          Fuel type: Diesel –          Easy management and upkeep –          Temperatures: 850 deg C for municipal waste 1000 deg C for medical waste 1100 deg C for harmful waste containing halogenated organic substances with content of chlorine or its compounds.
Demands and specs for the process of supply, installation, operation and make sure the three incinerators for burning and incineration of medications and also harmful compounds for customizeds branch Free 3 years warranty for incinerators from shipment day. In addition of complimentary added components ensure letter needs to be valid for 10 years from the […]
We’ve got a 70 bed medical facility in namibia. There’s a possibility of getting customers from several other regional doctors.
incineration Heater for burning patalogical (such as human blood or tissue ) as west The weight of this west stuff is 700 kg per month and we need an isolated heating system Without fume in addition to any sort of damaging gasoline . INCINERATOR SPECIFICATION # Summary Specification 1 Burning Capacity – – 400 kg/time […]
51. No    Attributes $_pecific tions 2.     Load capacity    300 – 4∞Kg (maximum) Warranty of one year from the date of commissioning. Separate   Annual    Maintenance    Contract   will be drawn with the provider at a later stage. bidding document 13.     Civil    works,    installation    and Onsite  demonstrationjperformance  evaluation and  adequate training of staff on the use […]
Automatic filling and refilling with capacity of 10 to 12 bunches per day working with gasoline therapy methods and gas fuel and also ought to obey the European Standards.the Federal Government Healthcare Facility for Medical Waste Incinerator with the adhering to Specifications. They are having fundamental wastes such as cells, plastic bottles etc, wastes originating […]
* A switch breaker for every engine (ventilators and also burners). Natural rubber, synthetic rubber, polyurethane sheet, and cumbersome movies, solids and also * The insulation of the burning chamber should be composed of refractory bricks, using a high content of aluminum and also insulates bricks in order to guarantee a minimum temperature on the […]
ADVANCED PYROLYTIC MEDICAL WASTE BURNER 1. NB.; Civil functions as well as any various other relevant solutions for the installment as well as training of drivers need to be contained in the burner’s rate. Requirements for the shelter of the burner: House of the incinerator comprehensive in deal (your home must have toilet as well […]
it’s additionally really critical for us to understand whether the device is qualified to manage cytotoxic waste as well as the characteristics in addition to disposal of treatment deposits. Moreover, operational requirements in regards to energy and also gas consumption, along with particularly the off-gas treatment system employed, birth substantial value, as meeting the requirements […]
50 kg/  hour  capacity incinerators ·        Burning Rate: 50kos/hr ·        Feed Capacity:  150kqs ·        Main Combustion  Chamber:  900 liters ·        Secondary  Combustion  Chamber:  300 liters ·        Mix Combustion  Chamber:  Yes ·        Smoke Filter Chamber:  Yes ·        Feed Mode: Manual ·        Power: 0.7Kw ·        Fuel Type: Diesel Oil/ Natural Gas/LPG ·        Internal Dimensions:  120 x 90 […]
Disinfecting/sterilizing the contaminated medical wastes, main combustion chamber, post combustion chamber, heat exchanger, ash removal units and flue gas treatment systems, with the following details: Hourly capacity of the system:           from 250 up to 500 Kgs/ hour Duration of operation:                        from 14 up to 18 hrs/ day Fuel type to be used:                         Diesel or other […]
Incinerator but the dimension of chamber > 2000 x >> 1200 mm. Prepare for melt FLUID Waste +/- 20 liter/hr. The chamber of the incinerator should be able to hold about 200 – – 250 kg of waste in an offered time. edical Waste Incinerators. The mobile system is our concern then the fixed systems. […]
common daily massacre involves 120 pigs. The Condemned item as well as also byproducts from the abattoir for Entry is around 1000 kgs.daily – – – – Heater capacity of damage of 350 kg/hour, calorific well worth of waste will surely be 13-25 MJ/kg [3,500 kcal/kg] and also ideal cozy ability 1,225,000 kcal/hr. – – […]
Chicken Burner – – – – 400 kgs feed per day.a tiny scale incinerator of shedding capability 30kg/hr= 1No. Note that it needs to be mobile as it is intended for oil regions service tented camps. It has to be diesel functioned as our location is remote. 150! Kg per human resources LPG electric burner […]
50 bed medical care centre in addition to additionally would enjoy to have your recommendation for burner that can effectively deal with the tons of 50 bed hospital.Incinerator for burnable garbage (paper & & & & natural) apparatus ability (100/150 lts). Bio Medical Waste Incinerators, Ability: 50kgs per hr Medical Waste Burner Design TS50 (PLC) […]
2 burners one with 500kg/day shed capacity another one with 1000kg/day thaw capacity 1 x Electrode 1 x petrol Filter 1 x Photocell 1 x Versatile pipe 1 x Nozzle 1 x Control Box in acinerator with 300 kg/ hr by twin filter moist in addition to dry.Pet Cadaver Incinerator upto 80 kg, gas operated […]
heaters that can handle Bio-Medical waste (red bag) from lab with level 2 in addition to 3, pet search study, and health centers. There are additionally a proportion of Pharmaceutical waste to be damaged. I would certainly like your referrals on what heaters would certainly handle these demand based upon the sticking to regular monthly […]
Model YD-100 Picture Burning Rate 100-150 kgs/hour Key Combustion Chamber 2000 Liters Second Combustion Chamber 500 Liters Feed Setting Handbook Voltage 220V/380V Power 2.5 Kw Gas Kind Diesel Oil Heater Italy Original Oil Intake (Diesel Oil) Average 28 kg/hour Gas Utilization (Gas) *** Inner Dimensions 180x115x98 centimeters (primary chamber) External Dimensions 270x185x280cm (without chimney) Temperature […]
Items/Model TS300( PLC) Principle Waste Incineration Treatment Burn Price Standard 250 kg/hour Control Mode PLC( Programmable Logic Controller Incinerator) Combustion Chamber 2000L Interior Dimensions 170x120x100cm Second Chamber 1000L Smoke Filter Chamber Yes Feed Setting Handbook Voltage 220V Power 2.5 Kw Oil Intake (kg/hour) Typical 28( DO) Gas Intake (m3/hour) *** Temperature Level Monitor Digital Screen […]
Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious  medical waste. The medical waste incinerators that has been effectively used to dispose of hazardous waste during  viral outbreaks like Ebola. HICLOVER.COM reaches temperatures of up to 1200oC and is able to destroy health care […]
HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Version CA50 Picture Waste Therapy Medical Waste Incineration Therapy Feed Capability Ordinary 100 kgs per feeding Burning Price Average 50 kgs per hr Burning Time per Feed Average 2 hr Control Mode PLC( Programmable Reasoning Controller Incinerator) Voltage 220V Power 1.0 Kw Gas Diesel oil Heater […]
Items/Model CA100 Photo Concept Medical Waste Incineration Therapy Burn Rate Standard 100 kg/hour Feed Capacity Average 200kg/feeding Control Putting PLC( Programmable Reasoning Controller Incinerator) Burning Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Handbook Voltage 220V Power 1.3 Kw Oil Utilization (kg/hour) Average 20.4 Kgs/Hour Gas Utilization (m3/hour) *** […]
Version WS-35 Photo Burning Price Average 35 kgs/hour Feed Capacity Average 80 kgs Main Combustion Chamber 460 Liters Secondary Combustion Chamber 200 Litres 3rd Burning Chamber 200 Litres Smoke Filter Chamber Wet Scrubber System Feed Mode Manual Voltage 220V Power 2Kw Gas Type All-natural Gas/LPG Heater Italy Original Oil Consumption (Diesel Oil) *** Gas Consumption […]
Items/Model TS30( PLC) Image Reduce Price Average 30 kg/hour Feed Capability Ordinary 60kg per feeding Control Mode PLC( Programmable Logic Controller Burner) Car Control as well as Display Burning Chamber 330L Inner Measurements 75x75x60cm Second Chamber 180L Smoke Filter Chamber Yes Feed Setting Manual Feeding Voltage 220V Power 0.5 Kw Oil Consumption (kg/hour) Ordinary 13.3 […]
Light Weight Small-Scale Medical, Mobile Optional Type Model YD-30  Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 […]
HICLOVER – Medical Environmental  Model YD-30 (Custom Edition) Picture   Burning Rate  average 30 kgs/hour Feed Capacity average 40 kgs Paimary Combustion Chamber 200 Liters Secondary Combustion Chamber 100 Liters Mix Combustion Chamber Yes Feed Mode Manual Voltage 220V Power 0.59Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) average 13.3 kg/hour Gas Consumption […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
incinerator manufacturer,medical incinerator,small scale incinerator,oil fired incinerator Items/Model TS100 Reduce Cost Ordinary 100 kg/hour Feed Capacity Average 200 kg/feed Control Mode PLC Combustion Chamber 1200L Internal Measurements 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7 Kw Oil Intake (kg/hour) 14– 28 Gas Intake (m3/hour) 10– 32.2 Temperature Level […]
Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set […]
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L 330L 560L 1200L Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm Secondary Chamber 50L 110L 180L 280L 600L […]
Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.medical-waste-incinerator.com Web: www.clover-incinerator.com Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless […]
Standard 30kgs per hr *** Crucial chamber( 200Liters) *** Second Room *** Mix burning chamber *** Stainless-steel smokeshaft( 1meter) *** Italy made oil burner( 2sets) *** Dry Scrubber *** Weight 1.7 T( can Reduce to 1.0 Bunch) Key Spare Parts( Standard for incinerator, and Cost consist of Now ): *** 2 collections Italy Oil Heater […]
Design for Pets Cremation Business Movable system & & Vehicle. Independent Placement for Small Pet Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business Model A1500 Picture Burning Rate Average 150 kgs/hour Feed Capacity Standard 350 kgs/feeding Primary Burning Chamber 1500 Liters Secondary Burning Chamber 500 Litres Mix Combustion Chamber Yes […]
Items/Model TS50M Picture Melt Price Average 50 kg/hour Feed Capability Average 50-150 per feeding Control Mode PLC( Programmable Reasoning Controller Incinerator) Combustion Chamber 450L Internal Measurements 75x75x80cm Added Chamber 225L Smoke Filter Chamber Yes Feed Mode Manual Feeding Voltage 220V Power 0.5 Kw Oil Usage (kg/hour) Average 13.3 Gas Usage (N.G, m3n/Hour) Average 16 Gas […]
Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core  HICLOVER – Medical Environmental    WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: www.medical-waste-incinerator.com  Email: [email protected]Email: [email protected]   Nanjing Clover Medical Technology Co.,Ltd.   smart
General specifications of a 100 kg/hr incinerator No. Description Parameter value     model   HICLOVER YD100 1 Machine working mode Oil + Power Oil + Power 2 Voltage 220V C 3 phase or 1 phase 220V 1P 3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average 33Liters/hour/total incinerator 3 burners 6 Incineration rate 100 kg/hr […]
Items/Model TS250( PLC) Photo Concept Waste Incineration Remedy Burn Rate Typical 250 kg/hour Feed Ability Standard 400kg/feeding Control Setting PLC( Programmable Reasoning Controller Burner) Combustion Chamber 2000L Inner Measurements 210x88x110cm Second Chamber 1000L Smoke Filter Chamber Yes Feed Setting Guidebook Voltage 220V Power 2.0 Kw Oil Intake (kg/hour) Average 24.2( DO) Gas Intake (m3/hour) *** […]