Category: waste-incinerator

Spare part list- ignition burner Item description                                                No of required Motor     2 Control box  2 Pump couplings   4 Photo cells    Two Sets ht. Sets electrodes    4 Oil valve       1 Nozzle   two   Parameter Compliance Type of Waste To treat medical waste, categories A,B,C,D,E Type of Incinerator Pyrolytic Nominal Burn rate 50 t0 60 kg/ hr […]
Incinerators to be very effective, fuel efficient with high / low capacity burn speeds The supply will include the particular equipment for successful waste management as stated above for a new personal environment contract management firm with planned operations 2013 in Indonesia and Thailand, and 2014 in West & East Malaysia to carry out those […]
    The incinerator shall be able to incinerate both liquid and solid as per data below;     Liquid waste to be incinerated   The sludge to be incinerated is composed exclusively of a water and oil mix in any percentage from the diesel power plant running on heavy fuel oil. A sample specs […]
30 August 2013 Last upgraded at 21:18 BST Five councils in south eastern Wales have developed a partnership to look after black bag waste in a proposal to minimize rubbish going to garbage dump. Write-up appreciated quote by the community Environment contributor Iolo ap Dafydd reports. Article priced quotation from the network
Ability: 20KG/Hr, Temp Variety: 600 Deg. C– – 1100 Deg. C Gas Supply: Natural Gas/Diesel Dual Burning Chamber Complete Scrubbing System (Dual Resulting Gas Washer), Double Blower, Chimney Elevation: 8m Electric Supply: 220/240Volt, Single Phase 1. 4. Duration– – heater will certainly be made use of every day: (Minimum 12 hrs) SOW 8. Fuel proposed […]
for Hospitals, Waste Keeping Track Of System, CSSD, Medical Facility Home furnishings as well as also Companies. We are based in the Resources city of Pakistan i.e. Islamabad, where you will find all the head offices of Armed forces in addition to Govt. establishments. We have the ability to Participate in tenders and we also […]
The sludge shall be properly atomized by means of compressed air in the burner in order to ensure complete combustion of the sludge. Both compressor and receiver shall be mounted on the same slide as the incinerator.     The incinerator shall also supply digital mimic window for tracking of the feed rate of the […]
Power Use: 75 KW (Initial Plenty ). MOC: Mild Steel Power Coated. Kind: Centrifugal Kind. { (adsbygoogle = window.adsbygoogle || []).push({});|} Capacity:2 HP/3Phase. Make of Electric Motor: Kirloskar/ Havells/Crompton.
4. Does it attend to control remedies to alter waste feed, grate speed, in addition to volume, circulation and also temperature level of major and also additional air? 6. Does this include system that instantly stops waste feeding when combustion standards aren’t ideal? 2. Can it be provided as a continuous system? 5. { (adsbygoogle […]
Capacity    less than 500Kg/hr. Fuel    it ought to be double system, such as diesel and natural gas. Operation    24hr-7days/week continuous operation. Retention time    Of the flow gases less than 2 Sec in the hot portion. Feeding System    Should be auto feeding system into primary chamber. Temp.     Wet System    If the machine equiped with a […]
Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of waste. The incinerator […]
Solid waste to be incinerated     Cartons,  rags,  cotton  and  other  wastes  associated  with  production of power loaded in the incinerator in bags. These pumps shall deliver waste oil from the incinerator sludge mixing tank to the incinerator. Operation and management of those pumps shall be completely automatic. A linear negative feedback control algorithm […]
NO All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal notice No. 121 of 29th September 2006 The […]
1) Policy – – – – Incinerator: 2) Waste Disposal Plan a)Classification it’s designed to sanitize medical waste, reduce its amount, and make its components unrecognizable all in one completely restricted in addition to automated system. Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste Rubber gloves, etc. General waste Gauze, etc. General Waste Plastic, Rubber Infusion […]
“PYROLYTIC” burning, by managing the gasification of waste The incinerator manufacturer need to remain clear of the launch of black smoke along with excellent dirt, during the loadings. It will certainly be able to lower the number of wastes by 98%. It shall have the capability to hold discharge in the next shed with gasoline […]
The incinerator shall also be equipped with special loading apparatus and mechanisms that allow safe incineration of solid waste simultaneously with liquid sludge. Loading of solid waste could be achieved through bags.   All intermediate piping, bellows and other fittings for connection between the tanks , burner, compressor and other equipment provided on the slide […]
The incinerator plant shall include a control board for its treatment. On the control panel we’ll have an aesthetic display of the chamber temperature level levels. This aesthetic screen should keep an eye and manage on the burner along with his performance. Ability of destruction in weight will be 60 Kg/h. It need to be […]
8.     The average dioxin and furan concentration in the emissions should not exceed 80ng/m3 total dioxins and furans if measured for a period of 6 to 16 hours. Note: 2.     Be paired with secondary burner/s burning gas or low sulphur liquid gas or some other suitable fuel. 3.     Ensure secondary air supply […]
The panel shall comprise of a compartment for the connection of power and control cables. Passage for power cables and control cables shall be produced by the bottom portion of the switchboard.         The drawer shall be locked in the remote place by padlocks.   1. Two systems are required to be […]
Stack size shall be in accordance with the manufacturer’s recommendations. Stacks are the forced-air kind and   completely self-supporting and unattached to neighboring structures. As a minimum, stack heights shall minimize   downwash of stack emissions due to aerodynamic influences from neighboring structures and be calculated according   with DoD 4715.05-G, Overseas Environmental Baseline Guidance […]
the next containerized incinerators. (Kitchen and accommodation and gray water and black water plant removing waste) we want incinerator is each function independent are all in 1 incinerator we need informed. Plant we installing for our accommodation barge used in an offshore marine construction project. 200 People would be accommodated onboard. programmable cycle The Incinerators […]
Petrol: diesel Consumption: 8-10liter/hour Capacity: to cremate (carrion and spoils) 350-400kg/hour Temperature: 900-1350?C Operation temperature: -30~40?C Incinerator weight: 1800-2000 kg Volume: 0.70-0.80m/cube Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) A heater stands for a whole service to the problem of disposal of clinical facility waste types. The liquid gas is petrol. The burner ought to meet the setup […]
waste itself, running problems in the shed chamber (i.e. temperature level, holding time as well as additionally disturbance) and also motorist capability. Waste having chlorinated materials (i.e. chlorinated solvents and plastics, PVC piping, lumber treated with pentachlorophenol or PCB-amended paint, aquatic driftwood) should be divided from different other waste because their burning will absolutely result […]
oElectro-ventilator distributing the secondary air, the regulation of the air flow being performed by valves and following the control of the automatic cycle. Controls and regulations: Control box watertight to dust, including:   A switch circuit breaker for each motor (ventilators and burners). A timer with adjustable temporization for the regulation of every burner. A […]
20. Fan: * An additional shot of air to ensure excellent oxygen material. The manufacturing facility; it will include also medical and preventative upkeep, as well as making use of equipment, etc NB.: Civil tasks as well as any kind of kind of various other related services for the configuration as well as likewise training […]
? Refractory concrete:. * A device of shot of air allowing a total recombustion of gases,. ? . Thickness: ≥ 75 mm.{ (adsbygoogle = window.adsbygoogle || []).push({});|} 18. High web content of aluminum and likewise protects bricks to be able to make sure a minimum temperature level on. ? * Length of the refractory;
* A heater of light which the usage is restricted to the ignition of waste. 15. Fuel: diesel.{ (adsbygoogle = window.adsbygoogle || []).push({});|} 5. ” PYROLYTIC” burning, by looking after the gasification of waste. ? The Temperature levels of burning: Minimum will be 850oC as well as likewise max 1400oC 7. It must have the […]
CONSTITTUTION DE L’APPAREIL. ? Ventilateur centrifuge. ? Tuyauteries de distribution d’air. A la mise en route du four les deux br?leurs sont allumés pour assurer la température minimale d’au moins 1100 ° C? ; ils restent en marche successivement pour maintenir la température constante. 3. BRULEUR DE LA CHAMBRE DE COMBUSQTION. 1-2Un poussoir hydraulique assurera […]
Logic Programmed Control of 2 Burners Array Of Pre-Set Burn Times Fuel Saving Burner Efficiency Control Program with Constantly Running Fans Temperature Monitoring With Separate Displays for Primary/ Secondary Chambers Auto Control Manual Control Timer Control 0-24 Hours Integral Fun Timer Control     Operating Features   Time to Temperature: 35 Minutes Gas Consumption: Gas […]
This Server Pack (Supplied As Part of the Machine) Constitutes Sufficient Parts to Keep the Machine Adequately For A 3 Years; the Parts from the Kit Mainly Related To Diesel Fired Burners and Are As Follows;   Thermocouple Temperature Sensor -2 Burner Blast Tubes -3 Burner Diffuser Assemblies -3 0.65 Dia: Nozzles -4   There […]
Capacity 100 kg/hr of waste containing up to 85% moisture     Two fully automatic, oil fired, pressure jet burners   Panel board   Diesel tank of capacity 250 It. with 2 diesel pipelines, filter and valve. The incinerator shall be ignited with light gas oil and will automatically switch over to burning sludge or […]
RECYCLABLE WASTE    PLASTIC (NON-PVC)     218,693 Temperature Controlled Burner. Incinerators to be made to meet the Norms of Pollution Control. Technology: Heavy-duty casing, to be a quality, rugged, dependable, economical Incinerator with relevant control, easy to operate and self explanatory. Units to be pre-assembled, pre-piped, pre-wired & tested before Transfer / Export. Note: Similar Technology […]
Our normal activities produces 2-5 plenty of different waste items daily which vary from condemned carcasses, along with medical burner primary combustion cost other wastes all that will need to be blazed at above 800Centigrade gauged flue exhaust gas.To be made use of by small medical care centers in addition to facilities to securely take […]
Quelling system/Heat exchanger Have to be made and generated from anti rust and acid assault goods such as stainless-steel 316 or comparable. Chemical application It should be equiped with the correct autochemical application system to deal with the pH for the water of the wet scrubber system such as picking up systems. Retention time Of […]
2.     4    Opacity of the smoke shouldn’t exceed 20% Viewed from 50 meters with naked eyes EM    = Measured emission concentration Vanadium                                     V Arsenic                                       As (adsbygoogle = window.adsbygoogle || []).push({}); 2.     Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any suitable fuel. 3.     Ensure secondary air supply […]
  The charging system shall include, as a minimum, a hopper for top feeding and mechanically operated hydraulic   charging pliers or augur. To prevent warpage or excessive thermal expansion, a charger cooling system using either   atmosphere or water shall be supplied.   Primary combustion chamber shall be either the rotary- or stationary fixed-hearth […]
WASTE HEATERS SUGGESTIONS china clinical burner Capability ? Ordinary Daily Max/Min June Temperature Level Level, 21-39 ° C.? Ordinary Daily Max/Min January Temperature Level Level, 2-12 ° C. (adsbygoogle = window.adsbygoogle || []).push({}); Gas/ keys power operated,. ? Disposal of both non-hazardous in addition to infected products flows (per waste inventory). ? Incinerators must have […]
waste burner manufacturer china, Waste chamber Timer control 0-12 hrs. Huge complete dimension leading bunches door together with fluid retention sill. Ash elimination door. Containerization: 20 foot delivery container with incinerator fitted. (adsbygoogle = window.adsbygoogle || []).push({}); Ancillaries: Operating and maintenance manuals. (30.5 centimeters), 16 range (1.52 ″″″. Control Board: Control of 1 heater. Vital […]
2. Warranty: booth systems will need to be provided 3 years service warranty from the day of acceptance. All called for extra components, preventative maintenance repair work as well as likewise corrective upkeep demand to be consisted of in the cost as well as supplied to the client. 11. System needs to get automated ignition […]
Secondary combustion chamber shall be either the rotary- or stationary-hearth (or kiln) type incinerator designed to   oxidize (or burn) the organic vapors and gases. Burner and combustion air controllers shall be fully automatic Diesel incinerator of 25Kg / h     Box Box dimensions of the incinerator.   Approx Width: 900 mm Approx: 1000 […]
·         Two combustion chambers ·         Ecologically friendly ·         Up to 50kg of waste / hour ·         To be used for animals medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: – ·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste ·         […]
Lately among clients informed us their goal to procure 1 system Gas Incinerator.medical waste burner to shed the wastes of university hospital in Egypt, the capacity asked for is 5 tons per day.the moderate heater that takes advantage of both electricity as well as likewise oil.A SMALL PET CREMATORY WITH GAS
In a very simple design with a metallic steel drum electric. including: Stainless steel chimney, 3.5 meters above the incinerator. A turbine  letting the supply of the atmosphere. External Dimensions Ave time for Burnout     5 hrs Chinese incinerator manufacturers, We procedure 8-10 ton waste of sheep carcass and its byproduct per day. We are […]
The Incinerator Plant is outcome wastes incineration from various petrochemical devices. In this task we want to blaze all result wastes from petrochemical gadgets and also additionally produced high stress steam from heater plant heat generated. { (adsbygoogle = window.adsbygoogle || []).push({});|} In the starting outcome waste from petrochemical collects and also moves to transit […]
Minimum capacity: 500L Provided with supporting structure valves Level Index tank funnel Filter impurities at the mouth of the tank     Especifica??   Incineradora a Diesel de 25Kg/h     Caixa Dimens?es da caixa do incinerador.   Largura aprox: 900 millimeter Comprimento aprox: 1000 millimeter Altura aprox: 1000 millimeter   Dimens?es da chaminé   […]
chemical repetitions to be utilized: 6mm plate steel sheel building 7. Total dimensions shall enable positioning the unit on a cars and truck arrangement. 5. Inlet tension and anxiety: as high as 2 bars; Separate Ash Door Second Heating system (petroleum ) -900,000 btu. Exhaust Stack-46cm x 6m. Weight System-5.700 kg. Dimension “D” -152 centimeters. […]
  930 to 980 C (1700 to 1800 F), but shall not to exceed 1150 C (2100 F). The ash-removal system shall consist of, as   a minimum, the direct manual removal into a sterile   Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be offered with   […]
medical waste incinerator china, Design, supply and manufacture ex Functions of a Single Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: – ·         Waste type: Mixed Form o,1,2,3,&4 hospital/clinical bio hazard waste ·         Waste density: 125 to 350Kg/M3 ·         Waste CV: 4000 KCAL/kg ·         Moisture content: 10-25% ·         Estimated ash residue: 5-10% ·         […]