News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak, as the country reported 830 confirmed cases of pneumonia, caused by the virus and 25 deaths by the end of Thursday (Jan 23). By Thursday midnight, Hubei Province in central China reported 549 cumulative confirmed […]
———————————– Failure to establish the authenticity of the certificate the bidder is liable to render the bid non-responsive and bidder open to action in the line with applicable regulations and act. Original catalogue must be submitted Original data sheet must be submitted Solidifier (Fluid waste disposal Product) Particular Features of Solidifier 21b jar […]
50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Variation YD-50 Burning Cost Average 50 kgs/hour Feed Ability Typical 150 kgs Primary Burning Chamber 900 Litres Additional Combustion Chamber 300 Litres Mix Burning Chamber Yes Smoke […]
30kgs per hour(average) medical waste incinerator, design dual combustion chambers(primary chamber and secondary chamber), smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small hospital medical waste treatment. Buy waste incinerator, find hiclover Items/Model TS30 PLC Idea Waste Incineration Burn Rate Criterion 30kgs/hour Gas Kind Diesel Oil/Natural […]
1) Policy – Waste disposal management shall be taken special note to reduce hospital infection. – Infections wastes shall be managed, stored strictly and burnt by a incinerator located at hospital website. 2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows; Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste […]
Waste Incinerator Door: Side/Front Opening Door VS. Top Opening Door Things Side Loading Door Top Loading Door Suggestion Price Cheap High cost Manufacture Tech. Easy A clutter tough Safty safe a lot more secure Burner Creating L/ I L Filling up hands-on huge door can be by Forklift Land project little big Ash door exact […]
The incinerator shall be equipped with water injection nozzle link. If the temperature in the primary chamber should rise too high (normal temperature between 300 and 800? C) during the working time, the automated water injection shall be actuated to decease the temperature. The incinerator shall have the following features and facilities:- a- […]
The incinerator shall be supplied with a range of interconnecting ductwork between the thermal reactor outlet and the inlet of the chimney. This ductwork will consist of refractory lined tubes and higher temperature resistant tubes made from rolled sheet steel of minimum 3mm thickness, welded along the length. The standard chimney shall be made […]
“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must prevent the discharge of black smoke and fine dust, during the loadings. It shall have the ability to reduce the quantity of wastes by 98%. It shall have the ability to hold emission in the second burn with gas residence of not less […]
The incinerator to be completely assembled logic and wired function tested in the factory, before dispatch. – One high flue gas temperature indicator/alarm to provide an audio/visual warning in case of high flue gas temperatures occurring in two phases:- First stage audible alarm, second stage incinerator shutdown, with a single voltage free contact […]
* Burner with fuel, mono-bloc casting directing type with flat flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. * A regulator with electronic viewing for the temperature of combustion. 23. The installed incinerator must bear a one year guarantee. 22. Process Filtering system: Scruber to […]
This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, etc. HICLOVER Incinerator supply updated models with dual combustion chamber, mix-combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Tools Technical Specifications Version YD-10C Image Feed Capability Common 40 kgs […]
Incinerator Model A1500, Intro Construction is dual/double combustion chamber with 03 units oil/gas burner, batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). Primary & Secondary combustion chambers and included mix-combustion chamber, smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load on the bottom of chamber. Incinerator panel control suit for […]
Animal Crematory Burner Ability: Regular 80kgs per feeding Thing Spec Design A900 Interior Measurements 120 x 90 x 85 CM Match for Family Pet Feline – – – – yes – Family pet – yes Pig – – small Cow – – no Key Product Checklist Key Burning Chamber Additional Burning Chamber Mix-Combustion Chamber Smoke […]
This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil/gas burner. Waste feed chamber is around 900Liters (0.9m3, YD-50). Primary & Secondary combustion chambers and included mix-combustion chamber. Waste load on the bottom of chamber. Incinerator panel control suit for local operation. Design YD-50 with […]
include automatic stop/start programmed timer control, flame failure gear and ignition failure gear to close off the fuel supply in case of malfunction. The burners shall be mounted so that waste can’t block the fire ports. — Blood bags & tubing, gloves, Gowns, curtains, etc.. — Contaminated packaging: bandage etc Each burner shall be designed […]
Oil tank with 2000Liters capacity Items/Model TS150( PLC) Image Principle Waste Incineration Therapy Burn Rate Requirement 100-150 kg/hour Feed Ability Standard 750kg/feeding Control Setting PLC( Programmable Thinking Controller Burner) Text Steel 8mm thickness Chamber Product High Alumina Fire Brick Wall Surface, 1750 ℃ Rate Paint for outside face 800 ° C Rate Combustion Chamber 1570L […]
The incinerator plant will incorporate a control panel for its own operation. On the control panel we will have a visual display of the room temperatures. This visual display must control and monitor the incinerator and his performance. Ability of destruction in weight will be 60 Kg/h. It should be able to operate not less […]
(adsbygoogle = window.adsbygoogle || []).push({}); Incinerator Variation CA100, Summary combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke filter chamber with firebrick and refractory concrete chamber. Batch load on the bottom of chamber. Incinerator panel control suit for local […]
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour Oil tank smoke filter room Items/Model TS100( PLC) Image Principle Waste Incineration Therapy Burn Cost Typical 50-100 kg/hour Feed Capability Average 200kg/feeding Control Establishing PLC( Programmable Thinking Controller Incinerator) Burning Chamber 1000L Internal Dimensions 120x100x90cm 2nd Chamber 540L Smoke Filter Chamber […]
All particles of this waste should achieve a high degree of sterilization instead of just “disinfection” because of the continuous agitations Description of the Treatment Cycle of the chip i) Loading * The waste has to be loaded by falling bagged and or boxed waste into the open loading door on the vessel. * The […]
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc. […]
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150( PLC) Principle Waste Incineration Treatment Reduce Rate Average 150 kg/hour […]
Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container or 40′ container), with necessary Basic work, such as flooring, lighting, wiring, etc. Items/Model CA30 Picture Reduce Rate Common 10 kg/hour Feed Capability Average 30kg per feeding Control Establishing PLC( Programmable Reasoning Controller Burner) Combustion […]
Medical Waste Shredder Ability: Should be 150 liters. Should be capable to shred up to 100 liters of the treated waste. 7 The technology should be capable to deal with hospital waste including sharps such as needles, lancets, scalpels and soft materials like bandages. Must render the waste to be […]
Petrol: diesel Consumption: 8-10liter/hour Capacity: to cremate (carrion and spoils) 350-400kg/hour Temperature: 900-1350?C Operation temperature: -30~40?C Incinerator weight: 1800-2000 kg Volume: 0.70-0.80m/cube Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) An incinerator represents a comprehensive solution to the problem of disposal of all hospital waste types. The liquid fuel is diesel. The […]
The publications listed below form a part of this specification to the extent referenced. The publications are referenced in the text by basic designation only. A1) Technical Specification: Incinerators All types of diesel fired incinerators acceptable for HCW may be provided as long as they can safely treat medical waste. The equipment should be compliant […]
Piping and stack connection locations and sizes. Technical data including temperature rating and arrangement of refractory and insulation. Weights of unit and loading diagram of foundation. Evidence that contractor has coordinated support requirements with base design. Recommended anchorage to foundation. Seismic requirements apply. Submit calculations by professional engineer. Predicted external surface […]
Waste Heater Design TS150 PLC, Review Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Primary Combustion Chamber: […]
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — […]
Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Primary Combustion Chamber: ※Main Feature: — Double Combustion Chamber […]
The incinerator shall be equipped with a Diesel oil tank which will be supplied with DO from our DO tank located in the power station. The tank shall be equipped with level switches and proper solenoid valves for automatic filling of the tank. The tank shall also be equipped with a magnetic level indicator, level […]
Control Mode PLC( Programmable Reasoning Controller Burner) Face Oil Paint 800 ℃ Combustion Chamber 768 Liters (0.768 M3) Inner Measurements 1200x800x800mm Added Chamber 384 Liters (0.384 M3) Smoke Filter Chamber Yes Feed Setting Manual Voltage 210/240V 50Hz 1P Power 1.3 Kw Oil Intake (kg/hour) Average 20.4( D.O) Thermal ability( kw/hour) 166-332 Gas Consumption (m3/hour) *** […]
A chamber of short article burning of gases is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. * A […]
Supporting Gas Diesel Kind of Heating Unit Monoblock Automated heating units Temperatures Key Chamber: 800 ° C ± 50 ° C. Extra Chamber: 1300 ° C ± 50 ° C. Kind. 240 W. Pump pressure. * Make-up of the refractory Burning Capacity Max. Refractory thickness. 240 W. Vacuum pressure. 115 mm thick. Product. Type. Centrifugal. […]
Spare part list –Following burners Item description No of required Motor 2 Control box 2 Pump couplings 4 Photo cells Two Sets ht. Sets electrodes 4 Oil valve 1 Nozzle two Spare part list –Ram loader Item description No of required Reed switch 4 Seal kit 1 Medical waste incinerator Accessories -Clean […]
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day). Items/Model TS50( PLC) Image Idea Waste Incineration Therapy Melt Price Criterion 50-100 kg/hour Feed Capability Typical 200-300 kg/feeding Control Mode PLC( Programmable Reasoning Controller Burner) Optional Upgrade Containerized Mobile Kind Burner ISO 20′ ′ ′ ′ Complete Container Burning Chamber 560L Interior Measurements 1000x800x700mm 2nd Chamber 280L Smoke Filter Chamber Yes Feed Setting Guide […]
* medical incinerators, The insulation of the combustion chamber should be composed of refractory bricks, having a ? Refractory concrete : ? . * Composition of the refractory; ? * A device of injection of air allowing a Whole recombustion of gases,
We supply Double Chamber Incinerator with primary chamber size average 1570Liters and burnning rate 50kgs per hour,100kgs per hour,150kgs per hour,200kgs per hour. the incinerators are now ready for shipping. Contact with us for quick respond: +86-13813931455 Secret Product Listing per 01 collection Trick Burning Chamber Secondly Burning Chamber Smoke Filter Chamber Incinerator PLC Control Situation Smokeshaft:10.0 Meters […]
The heater with dual/double combustion chamber in addition to completely dry filter chamber, two gas burner from Italy created, hot sale version for small range waste result, the ability is 30kgs per hr in addition to likewise 50kgs per individual resources. We are famous small scale incinerator manufacturer and brand, dispatch incinerator products and best […]
HICLOVER now provides additional components such as: — — — — Burners (diesel oil, LPG or gasoline ) — — — — Facet for heaters — — — — Fire ropes — — Incinerator chamber maintenance items smart — — — — Air Follower
The switchboard shall operate in a room Using the following prevailing conditions: – Maximum ambient temperature of 40 0C – Maximum relative humidity of 95% – Saline atmosphere – Altitude: in sea level – Climate type: Wet and humid coastal States with cyclone associated to a small tropical island in the Indian Ocean MAIN […]
The panel and parts hereof shall have the following characteristics: End All metal parts shall get a treatment taking the prevailing environment conditions into account. The top paint color shall be the Manufacturer’s standard. Wiring is connected to terminals blocks in […]
All numbering will be carried out in compliance with the corresponding circuit diagrams and wiring record. Component Marking All elements inside the switchboard shall be marked for identification. The marking shall be effected by material resistant to the prevailing environment conditions. All […]
We seek a lasting growth consequently we are embracing an enduring medical waste monitoring system, that includes building a modern long-lasting incinerator that will certainly not only provide for our center yet also for the many other centers in the larger place of the location. Waste type: health care threat waste and standard waste (adsbygoogle […]
Throughput: 50kg/hr in a tiny calorific value of 4,000 kca/kg in addition to a typical mass density of 120kg/m3 for basic waste as well as 160kg/m3 for healthcare waste. Restricting constant solution restriction 1500? C. Waste density: 125 to 350Kg/M3 Maximum operating period: 12 hrs. Warm face item:. Normal intake: a minimum of 3Ltrs/hr. Trick […]
INCINERATEUR DE DECHETS HOSPITALIER hospital incinerator design SPECIFICATIONS TECHNIQUES. 5. CHAMBRE DE POST COMBUSTION ? Affichage des températures des deux chambres 2-3-Aménagement 5-3 -Accessoires ? Soupape de régulation de l’air soufflé asservi par la sonde du débit d’ oxygène 7. BRULEUR DE LA CHAMBRE DE POST COMBUSTION ? 6. PRODUCTION DE L’AIR COMBURANT DE LA […]
Basic Info. Model NO.:furnace for incineration of animal waste Export Markets:Global Product Description Secret Features:. * Free or minimal installation on site. . 3. Neighborhood & & Sea Port & Station: Municipal Strong Waste, etc.. . * One year guarantee on burner and also parts in supply. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate […]
All tags with text shall be in English. Earthing System All normal non-current carrying metal parts of the panel and related parts shall be secured to a common aluminum earthbar running the whole length in the switchboard. The earthbar shall be found in the lower part of the frame […]