Model A1500 (customer made model) Internal Dimensions 150 x 100 x 96cm Suit for Animal Cat – yes Dog – yes Pig – yes Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Wet Scrubber( Washing Tower)(Optional Part) Incinerator Control Case Chimney:10.0Meters *(Update to Stainless Steel, free cost) Italy oil […]
• A burn rate of 25 – 30kg/hr. • Consists of two chambers to ensure significant reduction of emissions and be capable of temperatures in the range of 800-1000˚c. • Incinerator must be of a low maintenance design, be diesel fuelled and need no more than 15 amp 220-250 V power. KW consumption per hour […]
Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(Update to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 150Liters Mobile Trailer for Incinerator Model YD-50C Burning Rate (kgs/Hour) Typical 20-50 kgs/hour Feed Capacity (kgs) Typical 80 kgs/feeding Equipment Weight 2500 kgs(Incinerator) Primary […]
PRIMARY CHAMBER Heavy-duty steel casing High quality refractory lining and insulation Large full size top load counterbalanced door SECONDARY CHAMBER Heavy-duty steel casing High quality refractory lining and insulation 2 second gas residence time 900kg (1.35m³) Burn Speed 150kg/h Avg Ash Residue 20ltr Operation 3% Avg Fuel Consumption p/hr Max. Operating Temperature 1320°C Temperature Monitoring […]
We finish this project in year 2010 to 2011 and delivery to Hochiminh port, Vietnam with 1×40’feet open top full container. Items/Model YD-500 Burning Rate (kgs/Hour) 500 kgs/Hr. Feed Capacity (kgs) 800 kgs Equipment Weight 13000 kgs Primary Chamber (Liters) 4000 Secondary Chamber (Liters) 1500 External Dimensions (cm) 320x220x460 Internal Dimensions (cm) 257x147x108 Oil Tank(Liters) […]
7. Ensure the oxygen content of the emitted gases is not less than 11%. 2. Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any acceptable fuel. 3. Ensure secondary air supply is controlled efficiently. 4. Make sure fire contact with all gases is achieved. 5. […]
There are 03 sets Model YD-100 delivery to Iraq between year 2013 to 2014. The incinerator use for local several construction sites and all fuel type is diesel oil. Items/Model YD-100 Burning Rate (kgs/Hour) 100 kgs/Hr. Feed Capacity (kgs) 200 kgs Equipment Weight 5300 kgs Primary Chamber (Liters) 1200 Secondary Chamber (Liters) 500 External […]
Incinerator Model YD-30 for Australia Melbourne customer. Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.medical-waste-incinerator.com Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd.
Types of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator Materials of construction: The incinerator will not have any asbestos, asbestos-containing substances, mercury thermometers, and mercury switches. Refractory materials shall have the ability to fulfill relevant standards under ISO TC33 and CEN/TC 187. Waste feed system into the combustion chamber batch […]
news from: http://www.chinadaily.com.cn/a/202002/01/WS5e347a86a310128217273ead.html WHO declares outbreak constitutes international public health crisis China vowed on Friday to work with the international community to uphold regional and international health security, and reiterated it’s the confidence and capacity to win the battle against the novel coronavirus epidemic, which has claimed 213 lives throughout the country as of Thursday. The […]
a DUCK farm incinerator, We Have to buy a medium size incinerator for biological waste, more Particular DUCKS.a pet crematorium in ireland.Equipment Double chamber medical infectious waste incinerator Ability 10-30 Mph Characteristics of waste heating value over 2000 kcal/kg (8370 kJ/kg); articles of combustible matter over 60%; articles of non combustible solids below 5 percent; […]
News from: https://www.thestar.com.my/news/nation/2020/01/26/wuhan-virus-china-mobilises-medical-teams-to-fight-new-coronavirus WUHAN (Bernama): China is mobilising medical staff to aid Wuhan, the centre of the novel coronavirus (2019-nCoV) outbreak, as the country reported 830 confirmed cases of pneumonia, caused by the virus and 25 deaths by the end of Thursday (Jan 23). By Thursday midnight, Hubei Province in central China reported 549 cumulative confirmed […]
installation of waste disposable system in airport.Incinerator with oil burner – The layout should prevent any discharge of polluting substances into soil, surface water and groundwater. – Combustion zone has to reach at least 860 degrees under the most adverse conditions with at least 6% oxygen. Since it will treat hazardous and organic waste, temperature […]
50kgs per hour incinerator with two chambers suppliers from china *Aveage 50kgs per hour *Double chamber and double burner *900liters primary combustion chamber *Italy burner *Stainless steel chimney Model YD-50 Burning Rate Typical 50 kgs/hour Feed Capacity Typical 150 kgs Main Combustion Chamber 900 Liters Secondary Combustion Chamber 300 Liters Mix Combustion Chamber Yes Smoke […]
30kgs per hour(average) medical waste incinerator, design dual combustion chambers(primary chamber and secondary chamber), smoke filter chamber, PLC auto. control system, 0.33m3(330liters) primary combustion chamber, italy oil or gas fuel burner. for small hospital medical waste treatment. Buy waste incinerator, find hiclover Items/Model TS30 PLC Principle Waste Incineration Burn Rate Average 30kgs/hour Fuel Type Diesel Oil/Natural […]
The tenderer shall provide hydrostatic oil contents gauge (level index ) or a Centre line near the outlet connection. iv) 2No. Photo-electric cells Two sets of operating and maintenance manuals (both for the incinerator and burners) must also be provided. Including two sets of control schematic diagrams for all of the controls and wiring. 1.1.7 […]
hazardous waste disposal incinerator http://www.military-camps-incinerator.com/ Incinerator Items/Model HICLOVER TS100(PLC) HICLOVER TS150(PLC) Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour Feed Capacity(Average) 200kg/feeding 300kg/feeding Control Mode PLC Automatic PLC Automatic Primary Combustion Chamber 1200Liters(1.2m3) 1500Liters(1.5m3) Internal Dimensions 120x100x100cm 1500x1000x1000mm Secondary Chamber 600L 750Liters(1.0m3) Smoke Filter Chamber Yes Yes Feed Mode Manual Manual Voltage 220V 220V Power 0.7Kw […]
Incinerators must be able to support different power sources (PV solar system , diesel Electric generator , local or compound mini-scale grid).Each unit shall include a complete vertical exhaust and stack system, including the following features: • Steel construction. Packing Details Serie No. Part Name Size(M) Weight(Kgs) 01 Incinerator Mainbody 1.8 x 1.2 x 1.7(LxWxH) […]
Waste Incinerator Door: Side/Front Opening Door VS. Top Opening Door Things Side Loading Door Top Loading Door Reference Price Cheap High cost Manufacture Tech. Easy A litter difficult Safty secure safer Incinerator Shape L/ I L Loading manual big door can be by Forklift Land occupation small big Ash door same with feeding door or […]
Each incinerator shall be supplied with all necessary assembly/disassembly tools. Spare parts and consumables The proposed incinerator systems shall include all necessary spare parts, PPE, and consumables required for 2 years of operation. https://twitter.com/i/status/1578045332285698049 Incinerator Items/Model HICLOVER YD30(PLC) Burn Rate (Average) 30-50kg/hour(Medical Waste) 10-15kg/hour(Pet Animal Cremation) Feed Capacity(Average) 40kg/feeding Control Mode PLC Automatic Primary […]
The incinerator will have chimney, castable high quality refractory liner and incinerator shell, perforated blind for the primary and secondary combustion chambers and air circulation system. • FD fan • 25mm diameter flame valve • Fully wired control panel The bulk oil storage tank will have a capacity of 10,200 litres and be placed at […]
This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, etc. HICLOVER Incinerator supply updated models with dual combustion chamber, mix-combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C. Equipment Technical Specifications Model YD-10C Picture Feed Capacity Average 40 kgs […]
•Draft Equipment Sulphur Dioxide (SO2): 45 ppmv, 12-hour average as measured by a CEMS; 1Provide a sectional, circular cross section exhaust stack of the kind, size, and number of segments in compliance with the needs of the stack and refractory manufacturer to adequately support the refractory lining, permit growth, and prevent cracking of the refractory; […]
Incinerator Model A1500, Overview This model is big-scale animal cremation equipment for big animals. Construction is dual/double combustion chamber with 03 units oil/gas burner, batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). Primary & Secondary combustion chambers and included mix-combustion chamber, smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load […]
Animal Crematory Incinerator Capacity: Average 80kgs per feeding Thing Specification Model A900 Internal Dimensions 120 x 90 x 85 CM Suit for Animal Cat – yes Dog – yes Pig – small Cow – no Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(Update to […]
Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Gal annealed) by Hot-Dip Process FM GLOBAL (FM) SECTION 11 82 21 Page 6 High-Strength Low-Alloy and High-Strength Low-Alloy with Improved Formability, Solution Hardened, and Bake Hardened The incinerator will be of the controlled atmosphere kind, designed for (6-8) hour-day surgeries and rated at 75 mph. MEDICAL WASTE INCINERATORS […]
This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil/gas burner. Waste feed chamber is around 900Liters (0.9m3, YD-50). Primary & Secondary combustion chambers and included mix-combustion chamber. Waste load on the bottom of chamber. Incinerator panel control suit for local operation. Model YD-50 with […]
We strive for a sustainable development therefore we are adopting a sustainable medical waste management system, including building a modern sustainable incinerator which will not only cater to our center but also for the other centers in the larger area of the region. We’re aware that we need a modern incinerator that will not burden […]
Oil tank with 2000Liters capacity Items/Model TS150(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 100-150 kg/hour Feed Capacity Average 750kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Main Body Steel 8mm thickness Chamber Material High Alumina Fire Brick Wall, 1750℃ Rate Paint for Outdoor face 800°C Rate Combustion Chamber 1570L Internal Dimensions 150x100x105cm Secondary Chamber […]
Eductor air. Cooling of exhaust gases from 900 — 1000 0 C to around 350 0 C. IV. Eductor Assembly for : indicators and 3. Type of fuel : LDO / HSD Waste, moisture content, calorific value, etc. and shall vary from waste to Without stack Burners temperature controlled (TIC — Thermocouple) and operate on […]
Incinerator Model CA100, Overview 100Kg/Hour Burning rate with Secondary burning Capacity combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke filter chamber with firebrick and refractory concrete chamber. Batch load on the bottom of chamber. Incinerator panel control suit for […]
Waste Incineration Treatment Burn rate (rate of waste incineration) -at least 50 kg per hour Oil tank smoke filter chamber Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1000L Internal Dimensions 120x100x90cm Secondary Chamber 540L Smoke Filter Chamber Optional Feed […]
General The chimney will have a minimum height of 4 meters above ground level; One year Spare Parts Package for complete maintainability Fuel Diesel/LPG/LNG, please indicate The minimum exit velocity of the emissions will not be less than 10 metres/second; Temperature Warnings Minimum working temperature 920 °C, please indicate 4. Evidence their product meets […]
HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc. […]
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel… Items/Model TS150(PLC) Principle Waste Incineration Treatment Burn Rate Average 150 kg/hour *(50/100/200kgs/hour […]
Primary combustion Burn Rate 50kg/h minimum Weight (kg), please indicate: Secondary Chamber Gas Retention Time – 2 Seconds Fuel – Diesel/LPG/LNG, please indicate Power Supply for Control Box – 220V-240V 50Hz single phase Minimum working temperature 850 °C, please indicate One year Spare Parts Package for complete maintainability Both primary and the secondary temperatures maintained […]
Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container or 40′ container), with necessary Basic work, such as flooring, lighting, wiring, etc. Items/Model CA30 Picture Burn Rate Typical 10 kg/hour Feed Capacity Typical 30kg per feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber […]
Key Features: — Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator. — Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators. — System solutions for medical waste environmental. — […]
Waste Incinerator Model TS150 PLC, Overview Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Primary Combustion Chamber: […]
Incinerator dimensions: max 2000x1200x3200 mm Charging rate: Gas:- Natural Gas Gasified incineration for burning medical wastes. Gas type: Natural Gas – Secondary burning room max 0.5 m3, Size of the filling entry: max 650×850 mm • Electrical panels – Gasification room max 0.7 m3, Minimum installation and start up time Width (mm): 1280 or […]
Waste Incinerator Model TS150 PLC, Overview Construction is dual/double combustion chamber with 02 sets oil burner, batch load incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. Primary Combustion Chamber: […]
Ability per day around 8-10 kg wastage/day. · Which product do you provide, only incinerator or also compactor, shredder machine, any other equipment associated with waste treatment? · For the incinerator, can you suggest (and of so please send us specs and price) incinerator for 25 kg/hr, 50 Kg / hr, 100 kg / hr, […]
Average 50-100 kg/hour Burn Rate Items/Model TS75(PLC) Principle Waste Incineration Treatment Burn Rate Average 50-100 kg/hour Feed Capacity Average 200-300 kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Face Oil Paint 800℃ Combustion Chamber 768 Liters (0.768M3) Internal Dimensions 1200x800x800mm Secondary Chamber 384 Liters (0.384M3) Smoke Filter Chamber Yes Feed Mode Manual Voltage 210/240V 50Hz 1P […]
Incinerator Model TS250 PLC, Overview This model is small-scale waste incineration equipment for small waste output. Construction is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers and smoke filter chamber. Batch load on the bottom of chamber. Incinerator […]
50 to 60kg/hr and 100 into 120kg/hr diesel powered incinerator.1. 2. Required Incinerating Capacity: Approximately 4,500 tons per year. The incinerator must capable of incinerating type of waste mentioned or any combinations thereof at a rate of 3 mph. The machine shall be designed to operate for at least five consecutive times nonstop if required. […]
Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident moment. A combustion chamber of waste: * Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load * […]
incinerate mainly pharmaceuticals ( all types of dosage forms … syrups, tablets, injectables ) medical consummabables, and also biological fluids … 1.3FIELD TRAINING Test the incinerator under actual firing conditions. Verify with analyzing that all controls function within the minimum and maximum limits for temperature or time. Simulate actual unsafe conditions such as high temperatures […]